| Parker Compound: | FF102-75 |
| Temperature Range: | -15°C to 275°C (5°F to 525°F) |
| Test Samples: | 2-214 Size O-Rings |
| Specifications: | Black, Acid Resistant, 75 Shore A, Parofluor ULTRA Perfluorinated Elastomer |
| Property | Typical Results |
| Original Properties, ASTM D412,D2240,D297 Sore A Hardness Tesile Strength, psi Elongation, % Modulus @100% Elongation, psi Specific Gravity |
78 1609 119 1406 1.94 |
| Fluid Resistance, 70hours @ 70°C, ASTM D471 Butyraldehyde Hardness change, pts Tensile Change, % Elongation Change, % Volume Change, % | -3 -25 7 5.60 |
| Compression Set, 70 hours @ 175°C, ASTM D395 Method B, 2-214 Size O-Rings Set, % |
20.00 |
| Compression Set, 70 hours @ 230°C, ASTM D395 Method B, 2-214 Size O-Rings Set, % |
34.80 |
| 2-0xx O-Rings | 2-1xx O-Rings | 2-2xx O-Rings | 2-3xx O-Rings | 2-4xx O-Rings | 3-9xx O-Rings |
| Parker Chomerics | Flange Gaskets | Parofluor Seals | W L Gore |